Cảm biến ECW-XP2
Thông số kỹ thuật cảm biến khối lượng ECW-XP2
ECW-XP2+/ECW-XP3+ Inductive Elevator Loading Weighing Device Instruction Manual
- Type Selection:
- ECW-XP2+:Applicable to elevator with moveable car-platform in need of 2-channel signals as full-load and over-load.
- ECW-XP3+:Applicable to elevator with moveable car-platform in need of 3-channel signals as light-load, full-load and over-load.
| Application Range | Applicable to all elevators with moveable car platform in need of overload signal with a inspection clearance of 0~9.9/19.9mm | ||
| ⒉ | Sensitivity | ≤1%(electric quota) | |
| ⒊ | System Error | ≤3%(5~40℃) | |
|
⒋ |
Output Mode | Light-Load | Relay Dyn. Close; Operate for 10% Rated load (Not for ECW-XP2)
Relay Dyn. Close; Operate for 80% rated load Relay Dyn. Open;Operate for 100% rated load Contact Capacity:DC/AC 48V/500mA |
| Full-load | |||
| Over-load | |||
| ⒌ | Operation Ambient Temperature | -25~55℃ | |
| ⒍ | Power Supply | DC/AC 24V(±10%),Whole set operating current≤100mA | |
| ⒎ | Install Position | Elevator Moveable car-platform | |
| ⒏ | Overall Size | See Fig. 30X30X52.5mm3 | |
| Method 1:Load Autotuning
Applicable for accurate control output |
Method 2:Displacement Setting
Applicable for known system no-load to rated load displacement variation |
| No-load Positioning:
|
|
| No-load positioning Operation: | |
| End of Installation and adjustment | |
System Status Indication and Output:Status Indication of system to magnet from far to near
|
|
| Note:To extend to 0~19.9mm,it need to take Method 2 to let“Red light twinkling”more than 10 times. | |
- Output Operation Range:
| Payload W | Lightload (ECW-XP3+Specific) | Full-load | Over-load |
| Control Relay | J1 Dyn. Close | J2 Dyn. Close | J3 Dyn. Open |
| Operation Range | W>10% | 80%≥W≤100% | W>100% |
| LED Status Ind. | Green light twinkles | Red light twinkles | Red light shines |
- Others: