Cảm biến Wika 12719260
Item No. 12719260
Pressure transmitter Model A-10
Wetted parts: 316L
Non-linearity: 0.5% BFSL
Measuring range: 0…10 bar gauge
Process connection: G 1/4 A DIN EN ISO 1179-2 (formerly DIN 3852-E)
Sealing: NBR
Permissible medium temperature: 0…+80 °C
Output signal: 4 … 20 mA, 2-wire
Power supply: 8…30 V DC
Electrical connection: valve connector, size A
Approvals: cULus
Test protocol: with test protocol
pin assignment el. connection: UB=1, 0V=2
Vacuum and +/- measuring range
bar Measuring range -0.025 … +0.025 -0.05 … 0 -0.05 … +0.05 -0.05 … +0.15 -0.05 … +0.2
Overload safety ±0.2 ±0.2 ±0.2 1 1
Measuring range -0.05 … +0.25 -0.1 … 0 -0.1 … +0.1 -0.15 … +0.15 -0.16 … 0
Overload safety 1 ±0.2 1 1 1
Measuring range -0.2 … +0.2 -0.25 … 0 -0.25 … +0.25 -0.3 … +0.3 -0.4 … 0
Overload safety 1 1 1 3 1
Measuring range -0.5 … +0.5 -0.6 … 0 -1 … 0 -1 … +0.6 -1 … +1.5
Overload safety 3 3 3 3.2 5
Measuring range -1 … +3 -1 … +5 -1 … +9 1) -1 … +15 1) -1 … +24 1)
Overload safety 8 12 20 32 50
inWC Measuring range -10 … +10 -20 … 0 -20 … +20 -40 … 0 -40 … +40
Overload safety ±80 ±80 ±80 ±80 ±80
Measuring range -50 … +50 -60 … 0 -75 … +75 -80 … 0 -100 … 0
Overload safety 400 400 400 400 400
Measuring range -100 … +100 -120 … 0 -125 … +125 -150 … 0 -200 … +200
Overload safety 400 400 1,200 400 1,200
Measuring range -250 … 0
Overload safety 1,200
psi Measuring range -1 … 0 -30 inHg … 0 -30 inHg … +15 -30 inHg … +30 -30 inHg … +60
Overload safety ±3 45 60 60 150
Measuring range -30 inHg … +100 -30 inHg … +160 1) -30 inHg … +200 1) -30 inHg … +300 1)
Overload safety 250 350 450 600