Cảm biến TIM310
Thông số kỹ thuật cảm biến Sick TIM310-1030000
Measurement principle | HDDM+ |
Application | Indoor |
Light source | Infrared (850 nm) |
Laser class | 1 (IEC 60825-1:2014, EN 60825-1:2014) |
Aperture angle
Horizontal |
270° |
Scanning frequency | 15 Hz |
Angular resolution | 1° |
Working range | 0.05 m … 4 m |
Scanning range
At 10% remission |
2 m |
Mechanics/electronics | đại lý TIM310 | nhà phân phối TIM310
Connection type | 1 x 15-pin D-sub HD male connector (0.9 m) |
Supply voltage | 9 V DC … 28 V DC |
Power consumption | Typ. 4 W, 16 W with 4 max. loaded digital outputs |
Housing color | Light blue (RAL 5012) |
Enclosure rating | IP65 (IEC 60529:1989+AMD1:1999+AMD2:2013) |
Protection class | III (IEC 61140:2016-1) |
Weight | 150 g, without connecting cables |
Dimensions (L x W x H) | 60 mm x 60 mm x 79 mm |
Performance
Response time | 1 scan, typ. 67 ms
2 scans, < 134 ms 1 |
Detectable object shape | Almost any |
- At +45° to +225° of the working range; max. 150 ms at -45° to +45° of the working range.
- Typical value at 90% remission up to maximum scanning range; real value depends on ambient conditions.
Product data sheet | 2023-02-27 10:14:40
Systematic error | ± 40 mm 2) |
Statistical error | < 30 mm 2) |
Integrated application | Field evaluation |
Number of field sets | 16 field triples (48 fields, 1 triple (3 fields) can be configured directly at the scanner) |
Simultaneous evaluation cases | 1 (3 fields) |
1) At +45° to +225° of the working range; max. 150 ms at -45° to +45° of the working range.
‘ Typical value at 90% remission up to maximum scanning range; real value depends on ambient conditions.
Interfaces
USB | ✓ |
Remark | Micro USB |
Function | AUX, parameterization |
Digital inputs | 4 |
Digital outputs | 3 (PNP, additional 1 x “Device Ready”) |
Delay time | 67 ms … 30,000 ms (configurable) |
Dwell time | 67 ms … 600,052 ms (configurable) |
Optical indicators | 2 LEDs (ON, switching status) |
Ambient data
Object remission | 4 % … 1,000 % (reflectors) |
Electromagnetic compatibility (EMC) | |
Emitted radiation | Residential area (EN 61000-6-3:2007+AMD:A1:2011) |
Electromagnetic immunity | Industrial environment (EN 61000-6-2:2005) |
Vibration resistance | |
Sine resonance scan | 10 Hz … 1,000 Hz 1 |
Sine test | 10 Hz … 500 Hz, 5 g, 10 frequency cycles 1 |
Noise test | 10 Hz … 250 Hz, 4.24 g RMS, 5 h 2) |
Shock resistance | 50 g, 11 ms, ± 3 single shocks/axis 3) |
25 g, 6 ms, ± 1,000 continuous shocks/axis 3) | |
50 g, 3 ms, ± 5,000 continuous shocks/axis 3) | |
Ambient operating temperature | -10 °C … +50 °C 4) |
Storage temperature | -30 °C … +70 °C 4) |
Switch-on temperature | -10 °C … +50 °C |
Temperature change | -10 °C … +50 °C, 10 cycles 5) |
Damp heat | +25 °C … +55 °C, 95 % rF, 6 cycles 6) |
Permissible relative humidity |
Đánh giá